• HQ - 14480 Yorba Ave., Chino, CA 91710
  • 1-800-213-4528
ProductsInstrumentationConductivity/Resistivity

Conductivity/Resistivity

Conductivity/Resistivity

67 products found

Show products per page

Sort By:

Select products then
Change Display:

Showing 1 - 40 of 67

Page 1 of 2 Next >>

Go to page:

Filter Products
Secondary Sub Category
Manufacturer
Series
Type of product
Connection Material
Maximum PSI
Connection Size
Cell Constant
Number of Inputs
Number of Outputs
Connection Type
Type of Outputs
Cable Length
Thread Type
Electrode Type
Insertion Depth
Body Material
Electrode Material
Temperature Compensation
Item # and Description
Manufacturer
Price
+GF+ Signet
Quantity: 
Signet Conductivity/ResistivityElectrodes are designed to provide highly accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy andrepeatability. The standard electrode is constructed 316SS or Titanium, but there are other materials availabe. Reversible threads or sanitary flanges allow for maximum installation versatility.
+GF+ Signet
Quantity: 
Signet Conductivity/ResistivityElectrodes are designed to provide highly accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy andrepeatability. The standard electrode is constructed 316SS or Titanium, but there are other materials availabe. Reversible threads or sanitary flanges allow for maximum installation versatility.
+GF+ Signet
Quantity: 
Signet Conductivity/ResistivityElectrodes are designed to provide highly accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy andrepeatability. The standard electrode is constructed 316SS or Titanium, but there are other materials availabe. Reversible threads or sanitary flanges allow for maximum installation versatility.
+GF+ Signet
Quantity: 
Signet Conductivity/ResistivityElectrodes are designed to provide highly accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy andrepeatability. The standard electrode is constructed 316SS or Titanium, but there are other materials availabe. Reversible threads or sanitary flanges allow for maximum installation versatility.
+GF+ Signet
Quantity: 
Signet Conductivity/ResistivityElectrodes are designed to provide highly accurate sensing across a very broad dynamic range. These electrodes are built with a controlled surface finish to ensure accuracy andrepeatability. The standard electrode is constructed 316SS or Titanium, but there are other materials availabe. Reversible threads or sanitary flanges allow for maximum installation versatility.
+GF+ Signet
Not Available
The Signet 2839-2842 Conductivity/ Resistivity Electrodes are suitable for a wide variety of applications ranging from high purity water quality monitoring to weak acids and bases. The PEEK™ insulator and process connections are injection over-molded to minimize variance between electrodes.
+GF+ Signet
Call for Availability
The Signet 2839-2842 Conductivity/ Resistivity Electrodes are suitable for a wide variety of applications ranging from high purity water quality monitoring to weak acids and bases. The PEEK™ insulator and process connections are injection over-molded to minimize variance between electrodes.
+GF+ Signet
Call for Availability
The Signet 2839-2842 Conductivity/ Resistivity Electrodes are suitable for a wide variety of applications ranging from high purity water quality monitoring to weak acids and bases. The PEEK™ insulator and process connections are injection over-molded to minimize variance between electrodes.
+GF+ Signet
Call for Availability
The Signet 2839-2842 Conductivity/ Resistivity Electrodes are suitable for a wide variety of applications ranging from high purity water quality monitoring to weak acids and bases. The PEEK™ insulator and process connections are injection over-molded to minimize variance between electrodes.
+GF+ Signet
Quantity: 
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Not Available
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual inputs using any standard Signet conductivity/resistivity sensor. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 18.2 MΩ to 10 kΩ.
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Quantity: 
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Not Available
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual inputs using any standard Signet conductivity/resistivity sensor. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 18.2 MΩ to 10 kΩ.
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Not Available
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual inputs using any standard Signet conductivity/resistivity sensor. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 18.2 MΩ to 10 kΩ.
+GF+ Signet
Call for Availability
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Quantity: 
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Quantity: 
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Quantity: 
The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, or 10.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?S or a resistivity range of 18.2 M? to 10 k?. All 2850 units are available with a choice of two outputs: digital (S3 L) or 4 to 20 mA. The digital (S3 L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi- Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant. Additionally, each range can be inverted and are field selectable by the user. All 2850 units are built with NEMA 4X/IP 65 enclosures which allow wiring connections with long cable runs of up to 1,000 feet (305 m). EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A calibration tool is available for validation of the sensor electronics according to USP requirements.
Typical applications:
  • Water Treatment & Water Quality Monitoring
  • Reverse Osmosis
  • Deionization
  • Demineralizer, Regeneration & Rinse
  • Scrubber, Cooling tower and Boiler Protection
  • Aquatic Animal Life Support Systems
+GF+ Signet
Not Available
The Signet 8850 Conductivity/Resistivity Transmitter is designed for multiple installation capabilities, simple set-up and easy operation, thus satisfying a broad range of application requirements. The 8850 comes equipped with two 4 to 20 mA loop outputs and two open collector relays. It is offered with a NEMA 4X/IP65 front panel with a self-healing window in a convenient ¼ DIN package for easy mounting. The 8850 can be configured via a simple menu system. In addition to programmable outputs the unit can also be set up to measure raw conductivity values.
+GF+ Signet
Not Available
The Signet 8850 Conductivity/Resistivity Transmitter is designed for multiple installation capabilities, simple set-up and easy operation, thus satisfying a broad range of application requirements. The 8850 comes equipped with two 4 to 20 mA loop outputs and two open collector relays. It is offered with a NEMA 4X/IP65 front panel with a self-healing window in a convenient ¼ DIN package for easy mounting. The 8850 can be configured via a simple menu system. In addition to programmable outputs the unit can also be set up to measure raw conductivity values.
+GF+ Signet
Quantity: 
The Signet 8860 Dual Channel Conductivity/Resistivity Controller is a two-channel input device equipped with three scaleable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with Signet Conductivity Sensors, form the perfect measurement and control system for water treatment applications and more. Two versions are available: once accepts AC line-voltage, the other low voltage DC for power. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA 4X/IP65 front panel with self-healing window in a 1/4 DIN package for easy panel installation.
+GF+ Signet
Quantity: 
The Signet 8860 Dual Channel Conductivity/Resistivity Controller is a two-channel input device equipped with three scaleable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with Signet Conductivity Sensors, form the perfect measurement and control system for water treatment applications and more. Two versions are available: once accepts AC line-voltage, the other low voltage DC for power. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA 4X/IP65 front panel with self-healing window in a 1/4 DIN package for easy panel installation.
Water Analytics
Call for Availability
The AM3422 sensors offer a compact design that allos installation into standard pipe fittingsin small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the degign also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage
Water Analytics
Call for Availability
The AM3422 sensors offer a compact design that allows installation into standard pipe fittings in small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the design also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage
Water Analytics
Call for Availability
The AM3422 sensors offer a compact design that allows installation into standard pipe fittings in small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the design also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage
Water Analytics
Call for Availability
The AM3422 sensors offer a compact design that allows installation into standard pipe fittings in small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the design also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage
Water Analytics
Call for Availability
The AM3422 sensors offer a compact design that allows installation into standard pipe fittings in small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the design also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage
Water Analytics
Not Available
The AM3422 sensors offer a compact design that allows installation into standard pipe fittings in small line sizes such as 3/4" and 1", avoiding the need for special flow cells. Simplicity of the design also allows them to be economically offered in exotic metals for especially corrosive chemical applications.

Wetted materials of construction are 316 stainless steel and Teflon®, with double o-ring seals at all points. The outer EPDM o-ring bears the brunt of process interface, allowing the back o-ring to maintain reliable sealing free from chemical attack. An integral temperature element tailored to the analyzer of choice allows automatic compensation for maximum accuracy. Leads are 10' standard, stripped and tinned ends or optional spade lugs.

Process connections are made via a bored through swage fitting with 1/2" or 3/4" NPT threads. This fitting can be screwed into a line, or tank and it can also be turned around and connected to a standpipe for use in a submersion configuration. The AM322 is good for general purpose and covers a broader range of conductivities.

The AquaMetrix AM3422 series is ideal for the following applications:
  • Plating
  • High Purity Water Applications
  • Pharmaceutical Applications
  • Reverse Osmosis Systems
  • Fume Scrubbers
  • Cooling Towers
  • Textile Manufacturing
  • Food and Beverage

Page of 2 Next >>

Close Menu