pH/ORP Sensors
Harrington proudly offers high-grade pH and ORP sensors, available in an extensive array of styles, materials, and specifications. Ideal for measuring the acidity and oxidation-reduction potential of liquid solutions, these sensors come in materials such as glass, plastic, and platinum. Browse our selection to request a quote, find more information, and review purchasing options.
Filter Products
Item # and Description
Manufacturer
Price
The Signet 8550 ProcessPro® Flow Transmitter converts the signal from all Signet flow sensors into a 4 to 20 mA signal for long distance transmission. It offers the unique feature of dual input and output capability.The 8550 has two optional relays for process control, two packaging options for integral/pipe mount or panel installation, and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability, signal stability, and simple user setup and operation.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2724-2726 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patentedDryLoc® connector. The large area PE reference junction and pathway isconstructed to increase the total reference effectiveness and ensureslong service life.The DryLoc® connector with foul-proof gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensorelectronics. The robust Ryton® threaded sensor body and choice offlat pH, bulb pH, or flat ORP sensing elements provides broad range ofchemical compatibility for a wide variety of applications.
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2734-2736 pH and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc® connector. The large area PTFE reference junction, salt bridge and reference electrode are constructed to increase the total reference effectiveness, resist chemical attack, and ensure long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2750 Sensor Electronics. The robust Ryton® threaded sensor body and choice of flat, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications. There is an optional pH sensing version available for applications with HF. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard pH glass in levels of pH 6 and below. The quick temperature response is available in a PT1000 temperature sensor and allows compatibility with the Signet 8900 and 9900 instruments. The 2734-2736 electrodes are ideal for a wide range of harsh applications. The sensors incorporate 3/4 inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings DN15 to D100 (1/2" to 4").
The Signet 2764-2767 Differential pH & ORP electrodes are built to handle even the most extreme and harshest of chemical applications.A key feature is the reference electrode which is protected in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides and metals. To ensure long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge. The patented porous PTFE reference junction resists fouling, clogging and chemical attack.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly. The choice of a PT-1000 or 3K? temperature sensor allows compatibility with all Signet pH/ORP instruments.
The 2760 is a preamplifier that allows anyDryLoc® pH/ORP electrode to work with most Signet instruments. It is also sold as a simple connector for use with other manufacturers instruments that do not require a preamplified signal.The 2750 comes with the same pre-amplifiedsignal as the 2760, but features two different outputs: a two-wire 4 to 20 mA loop output, or a digital (S3L) output which allows for longer cable lengths and is compatible with the Signet 8900 Multi- In-line 2750. Parameter Controller. The 2750 devices self-configure for pH or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple push-button calibration and includes an LED indicator for visual feedback.